PV Installation Material - 4.0 mm² - Black

MC4– and MC4– Evo-2 connectors are required between the module, inverter, storage unit and domestic mains, along with solar cable sold by the metre, pre-assembled cables, in-line fuses and the appropriate crimping tool, predominantly from Stäubli.

3 Items

  • Athilex Solar Cable H1Z2Z2-K 4 mm² Black – 100 m Roll

    Athilex · Item no. 14530041Athilex · 14530041

    Athilex Solar Cable H1Z2Z2-K 4 mm² Black – 100 m Roll

    €85.00

    incl. 0 % VAT for system operators*

    In stock · Free shipping

    Free shipping

  • Athilex 4.0 mm²H1Z2Z2-K, Black DCA Cable, 1 m

    Athilex · Item no. 14532031Athilex · 14532031

    Solar cable 4 mm² black

    from 5 m

    €0.99
    / m

    incl. 0 % VAT for system operators*

    In stock · plus shipping costs

    Plus shipping costs

  • Athilex Solar cable H1Z2Z2-K 4 mm² black – 500 m reel

    Athilex · Item no. 14530042Athilex · 14530042

    Athilex Solar cable H1Z2Z2-K 4 mm² black – 500 m reel

    €419.00

    incl. 0 % VAT for system operators*

    In stock · still 4 availableOnly 4 in stock · Free shipping

    Free shipping

* Section 12(3) UStG: only with the operator declaration at checkout, otherwise plus 19 % VAT.

PV cables and connectors comprise everything laid between the module, inverter, storage unit and domestic mains: solar cable sold by the metre, pre-assembled cables, Y-splitters and in-line fuses for the string, connection cables for storage units, ‘MC4’ connectors, and the tools required for them. Most parts are supplied by Stäubli, Athilex and Growatt.

The product groups

Solar cables sold by the metre and on reels: Athilex cables of the H1Z2Z2-K type with cross-sections of 4 and 6 mm², each available in red and black so that positive and negative can be distinguished on the roof. According to the Athilex data sheet, they are rated for 1,500 V and temperatures ranging from −40 to +90 °C. In addition, there is a green-and-yellow cable with a cross-section of 16 mm² for equipotential bonding.

Cable assemblies from Stäubli: in-line fuses rated at 15 and 20 A, which are plugged directly into the busbar, Y-splitters in both directions (two plugs to one socket and vice versa), used to combine two parallel busbars into a single cable, and a pre-assembled 4 mm² cable, 3 m in length.

Connectors from Stäubli: Plugs and sockets from the MC4 and MC4-Evo 2 systems for conductor cross-sections from 4 to 10 mm², branch plugs for MC4-Evo 2, and sealing caps to cover open plugs and sockets until connected.

Connection and lead cables for specific devices: Cable sets for the Growatt ARK storage systems (for the MOD-XH, SPH and SPF inverter series) and SAJ BC2-HV1, as well as 5-metre Schuko connection cables for APSystems EZ1-M, Deye and Growatt micro inverters (NEO 800M-X and NEO 1600M-X2). For these cables, the exact model designation of the device is decisive, not the brand alone.

Tools: Crimping pliers with inserts and a locator, wire strippers, cable cutters, mounting spanner, torque spanner and test probes for MC4 and MC4-Evo 2, all from Stäubli.

Two rules for cabling

Firstly: Connectors must only be mated with counterparts from the same manufacturer. According to Stäubli, plugs and sockets must not be connected to counterparts from other manufacturers; such connections lose their IEC and UL certification. Secondly: The cross-sectional area depends on the current and the length of the cable run. A larger cross-sectional area minimises losses over long cable runs; this is determined by the design, not by what’s left on the roll.

Neither of these points is visible in a finished connection. That is why the tool specific to the respective system must be included in the order, and the connectors are crimped, not soldered or clamped.

What’s next

The product groups have their own pages: solar cables, MC4-connectors, connection and link cables, Y-splitters and fuses, as well as crimping pliers and MC4-tools. Rails, roof hooks and clamps can be found under ‘Substructure’. Complete PV kits do not usually include solar cables; these are added here to match the cable route.

ACTEC supplies the materials but does not carry out installation. To connect the system to the domestic mains supply, please contact a qualified electrician; your network operator can provide information on the requirements.

Frequently asked questions about PV cables and connectors

What do I need a Y-splitter for?

A Y-splitter combines two modules or strings connected in parallel onto a single cable; the currents add together, so please check the inverter’s permissible input current. It is available in two versions, for the positive and negative sides: two plugs to one socket and two sockets to one plug.

When is an in-line fuse advisable?

It provides individual protection for a string, for example when several strings are connected in parallel. The appropriate rated current – 15 or 20 A – is determined by the modules’ technical data sheet and the system design.

Which cable is suitable for my storage system?

The connection cables are specific to a particular series, such as Growatt ARK for MOD-XH, SPH or SPF. The model designation in the data sheets for the storage system and the inverter is decisive.

Loading...